Permit: T01CM02717

Parcel: 141113580

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T01CM02717

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
07/31/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
07/30/2001 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*
07/27/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) ROWS NOT NAILED ON SOUTH GARAGE ROOF PLANE, ALONG WITH SOFFIT-STOPPED INSPECTION-CHECK ENTIRE ROOF 2) NAIL OFF SHEARWALL AT ENTRY 3) METAL DIAGONAL BRACING NOT NAILED OFF 4) PATIO ROOF LEDGER NOT CLIPPED 5) STUD CLIPS MISSING NORTH SIDE 6) STRAP ENTRY DOOR TOP PLATE INTERSECTIONS