Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 08/28/2001 |
ELECTRIC - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000* |
| 08/27/2001 |
ELECTRIC - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999* SEE NEC 336-18 NMS SECURED BY STAPLES @ PANEL.2.) HOLDOWN @ REAR SLIDER NOT REPLACED PROVIDE ALTERNATIVE APPROVED METHOD CHECK SOLE PLATE SPLICES FOR ANCHOR BOLTS MISSED GARAGE. |
| 08/23/2001 |
ELECTRIC - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*1.) ELECTRIC ROMEX NOT COMPLETE THRU OUT 2.) BLOCK MECHANICAL 3 SIDES MINIMUM 3.) PROVIDE POST UNDER GRIDER. 4.) ROMEX @ PANEL SHEATHIN NOT 1/4" IN BOX 5.)PROTECT CENTRAL VACUMM SYSTEM SECURE PER MANF SPEC. 6.) SECURE PET 4' O.C. HORIZONTAL 7.) SECURE 4 GANG ELECTRIC BOX. 8.) BLK BETWEEN UPPER STUBBED TRUSSES. 9.) FHA STRAP A SOLE PLATE SHOWER. |