Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 08/24/2001 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 08/23/2001 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*1.) HALL BATH UPSTAIRS LFCI OUTLET BOX LOOSE. 2.) DACCUZZI TUB PEX CONNECTED WITH INCORRECT CRIMP RINGS COPPER COLLER NOT ALLOWED. 3.) JACCUZI TUB PUMP REQUIRES AT LEAST A 14" X 14" ACESS PANEL. 4.) PROVIDE NOTORIZED LETTER OF PLAN & CODE COMPLIANCE FOR MECHANICAL INSTALLATION APPROVED BY CITY OF TUCSON. 5.) VACCUZI PUMP GFCI OUTLET MUST BE ACCESSABLE 6.) VACCUZI PUMP CANNOT USE AN EXTENSION CORD. 7.) ONE BATH AND ONE LIGHTING CIRCUIT BREAKER ARE DOUBLE LUGGED. |