Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 03/21/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 03/19/2002 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*PROVIDE LITERATURE ON FIRE CAULKING NEED DRAFT STOP OR PACK INSULATION. |
| 03/18/2002 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*1.) PENETRATIONS THROUGH FIRE WALL MUST BE DONE USING APPROVED FIRE BARRIER SYSTEM. PROVIDE SYSTEM & INSTALL ACCORDINGLY. SPACKLE & TAPE IS NOT AN APPROVED SYSTEM. 2.) HAS ROOF NAILING BEEN INSPECTED IT HAS NOT BEEN APPROVED ON PERMIT. 3.) PROVIDE DRAFT STOP @ SOFFIT BY ELECTRIC PANEL. (MINERAL WOOL BATTING MAY BE USED.) |