Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 08/09/2002 |
PLUMBING - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000* |
| 07/11/2002 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection 0000* |
| 06/10/2002 |
PLUMBING - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*/ 1) NO PRESSURE TEST ON POTABLE PLUMBING 2) NO WHOLE HOME DWV WATER TEST PER UPC SECTION 712.2 3) PROTECT ALL PLUMBING PENETRATIONS AT METAL STUDS WITH APPROVED ISOLATORS 4) NAIL/SCREW PROTECT ALL PLUMBING WITHIN 1 1/2" OF STUD SURFACE 5) KITCHEN ISLAND NOT VENTED 6) W/C FLOOR FLANGES NOT INSTALLED 7) PLUMBING OUTSIDE OF WALL CAVITIES |