Permit: T01CM02613

Parcel: 115020860


Addresses:

421 E LESTER ST

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
08/09/2002 PLUMBING - INTERMEDIATE Approved IVRS - Inspection 0000*
07/11/2002 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*
06/10/2002 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*/ 1) NO PRESSURE TEST ON POTABLE PLUMBING 2) NO WHOLE HOME DWV WATER TEST PER UPC SECTION 712.2 3) PROTECT ALL PLUMBING PENETRATIONS AT METAL STUDS WITH APPROVED ISOLATORS 4) NAIL/SCREW PROTECT ALL PLUMBING WITHIN 1 1/2" OF STUD SURFACE 5) KITCHEN ISLAND NOT VENTED 6) W/C FLOOR FLANGES NOT INSTALLED 7) PLUMBING OUTSIDE OF WALL CAVITIES