Permit: T01CM02613

Parcel: 115020860


Addresses:

421 E LESTER ST

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
08/14/2002 BUILDING - FINAL Approved IVRS - Inspection 0000*
08/09/2002 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) ABS PLASTIC VENTS ON ROOF MUST BE PROTECTED WITH LATEX PAINT 2) FILL OPEN TRENCHES 3) OUTSIDE HOSE BIBS NOT INSTALLED REQUIRE ANTI-SIPHON VALVES 4) OUTSIDE GFCI OUTLETS RWQUIRE WEATHER PROOF COVER 5) LABEL ALL CIRCUITS IN ELECTRIC PANEL 6) ALL GROUND WIRES MUST BE SAME GAUGE ON EACH GROUND LUG 7) VENT GRILLS REQUIRED 8) GARAGE GFCI CIRCUIT INOPERABLE 9) BARE BULB LIGHT FIXTURES NOT ALLOWED IN CLOSE CLOSETS 11) RANGE REQUIRES SHUT OFF VALVE 12) BASE BOARD HEATER NOT IN 13) TRIM CLEANOUTS TO GRADE AND INSTALL THREADED CAPS 14) WASTE VENTS WITHIN 10 FEET OF EVAPERATIVE COOLER MUST EXHAUST 12" ABOVE COOLER 15) NEED SPECIAL INSPECTION, INSULATED AND STUCCO INSTALLATION CERTIFICATES