Permit: T01CM02589

Parcel: 11521151F

Inspection Status: Approved

Inspection History: PLUMBING - ABOVE CEILING

Permit Number - T01CM02589

Inspection Description - PLUMBING - ABOVE CEILING

Inspection Status - Approved

Date Description Inspector Results Comments
04/03/2002 PLUMBING - ABOVE CEILING Approved
02/06/2002 PLUMBING - ABOVE CEILING Partial Approval IVRS - Inspection 0000*SEC PLAN FOR EXPANSION TANK NOT INSTALLED AT THIS TIME. REMOVE SANTEE ON 3 COMP SINK INSTALL APPROVED FITTINGS REMOVE NO HUB BANDS ON FLOW CONTROL & PROVIDE APPROVED TRANSISSION FITTINGS. ANCHOR RELIEF LINE NOT THINK ABOUT BACK FLOW PROTECTION FOR ICE COFFEE ECT. SEC PLAN VALVE AT METER SETS.