Permit: T01CM02589

Parcel: 11521151F

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T01CM02589

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
12/06/2001 PLUMBING - INTERMEDIATE Approved IVRS - Inspection 0000*NOTE ON PERMIT CORRECTIONS HAVE BEEN AS PER LAST REQUEST PLEASE HAVE PLUMBER FINISH FHA STRAPS AS NEEDED AT WASTE & VENT FOR 3 COMP SINK.
11/27/2001 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*FOR GREASE TRAP. SEC 94 UPC SEC. 1011.3 LOCATION OF FLOW CONTROL DEVICE 1.) READILY ACCESSIBLE VISIBLE LOCATION 2.) LOCATION IN TAIL PIECE ON 3.) LOCATION DRAIN OUT LET 4.) VENT FLOW CONTROL.
10/25/2001 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*SEC PLAN PLAN CALLS FOR 3/4 DROP TO GRIDDLE 3/4 DROP TO STEAM TABLE. THE DROP FOR STEAM TABLE NOT INSTALLED AT THIS TIME? PROVIDE APPROVED REVISED DRAWING FOR ANY CHANGE ON GAS LINES. ALSO HAVE PLUMBER PROVIDE A DRAWING ON THE INSTALLATION OF WASE FOR 3 COMP SINK TO GREAS TRAP AT TIME OF NEXT THANKS.
10/19/2001 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*
10/02/2001 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*1.) PLEASE PROVIDE HANGERS ON COPPER REMOVE WIRE 1" 3/4 & 1/2" 2.) SEE ISOMETRIC DRAWING FOR 3 COMP SINK PLEASE INSTALL WASTE LINEDO NOT INSTALL FLASHING 4.) ANCHOR ALL COPPER SEE 1/2 COPPER AT MOP SINK.
08/17/2001 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*