Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T01CM02583
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/11/2001 | BUILDING - FINAL | Approved | IVRS - Inspection 0000* | |
06/08/2001 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection 0000*/ 1) NO ONE ON SITE, CALLED 886-9291 THREE TIMES, BUSY 2) RE-CALL INSPECTION AND ARRANGE FOR ADULT TO BE AT INSPECTION | |
06/05/2001 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection 0000*/ 1) WIRING RUN IN WHITE PVC MISSING BUSHINGS AND CORRECT FITTINGS, USE ONLY SCHEDULE 80 ELECTRICAL CONDUIT 2) ALUMINUM AWNING ON WEST SIDE YARD, NOT ON PLAN GOES TO PROPERTY LINE 3) WOOD SIDING YOU NEED 6" TO EARTH SOUTH SIDE 4) T&P LINE REDUCED GOING TO OUTSIDE NEED FULL SIZED 3/4" WITH A 90 DEGREE ELBOW 5) DRYER VENT TO BE ALL METAL |