Date Description Inspector Results Comments
07/31/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
07/27/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) NEED 2 MORE HD'S IN FRONT 2) TRUSS CALC'S
07/23/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) NUMBER 1, 5, 8, AND 10 NOT DONE
07/20/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) SEVERAL ITEMS FROM 7/18/01 INSPECTION HAVE NOT BEEN CORRECTED
07/18/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) AB'S AT #4 AND #5 SHEARWALLS NOT PER SCHEDULE 2) SHEARWALL AT SOUTHWEST CORNER NOT NAILED PER SHCEDULE 3) STUD CLIPS MISSING WESTSIDE 4) MAS NOT NAILED FRONT PORCH 5) PROVIDE ALTERNATE HD'S WHERE SPALLING EXCEEDS 3" 6) WRENCH TIGHTEN ALL AB'S 7) FILL IN ABOVE HEADER AT GARAGE WINDOW 2ND FLOOR WESTSIDE 8) PROVIDE TRUSS CALC'S AT EXTERIOR CLIP INSPECTION 9) SOME JOIST HANGERS NOT NAILED 10) JACK TRUSSES REQUIRE LU24 HANGERS PER DETAIL (7/SD2)