Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit: T01CM02522

Parcel: 110045530

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
04/26/2002 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
04/25/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) MANY AREAS OF ROOF NOT NAILED 2) OSB ROOF PANELS MUST SPAN THREE TRUSSES (TWO BAYS) RIPPER S LESS THAN 12" NOT ALLOWED 3) RSP4 CLIPS NOT PROPERLY INSTALLED SEVERAL PLACES 4) PORCH LEDGER NOT CLIPPED-SEE 8/SD-2 5) STUD MISSING EAST WALL 6) INTERIOR BEARING TRUSSES NOT BEARING ON PLATES AND TRIMMER 7) HEADERS MUST BEAR ON TRIMMERS 8) 13/SD2 NOT COMPLIED WITH