Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 04/26/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 04/25/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) MANY AREAS OF ROOF NOT NAILED 2) OSB ROOF PANELS MUST SPAN THREE TRUSSES (TWO BAYS) RIPPER S LESS THAN 12" NOT ALLOWED 3) RSP4 CLIPS NOT PROPERLY INSTALLED SEVERAL PLACES 4) PORCH LEDGER NOT CLIPPED-SEE 8/SD-2 5) STUD MISSING EAST WALL 6) INTERIOR BEARING TRUSSES NOT BEARING ON PLATES AND TRIMMER 7) HEADERS MUST BEAR ON TRIMMERS 8) 13/SD2 NOT COMPLIED WITH |