Permit: T01CM02497

Parcel: 118038250


Addresses:

2582 W SUNSTAR PL

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
10/04/2001 FRAMING Approved IVRS - Inspection 0000*
10/03/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) CLEANOUT AT MASTER BATH CANNOT BE AT A HORRIZONTAL 2) NON-BEARING STUD OVER NOTCHED AT MASTER BATH 30 SECURE PEX AT MASTER TUB 4) SHIM HEADERS 5) CLIP DOUBLE STUDS AT HEADER OF DOUBLE GRIDS 6) SECURE HOOD VENT 7) A.B.'S LOOSE THROUGHOUT 8) REVISE B-7 TO SHOW AS BUILT 9) STRAP DOUBLE PLATE