Permit: T01CM02492

Parcel: 137338090

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
07/11/2001 FRAMING Approved IVRS - Inspection 0000*
07/10/2001 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) SMOKE DETECTOR SHALL BE INSTALLED IN HALLWAY ENTRANCE TO BEDROOMS SEE SHEET 9A NOTE #3 2) CRUSHED AIR DUCT AT LAUNDRY ROOM 3) SEAL FLOOR AT LAUNDRY DRAIN TO PROTECT FROM INFILTRATION
07/09/2001 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) WORK CRAWL SPACE IN ATTIC FOR HORIZONTAL FURNACE NOT COMPLETE 2) PROVIDE POSITIVE SUPPORT AT VTR 3) SECURE VALVE BEHIND MASTER TUB AND SHOWER 4) ISOLATE PEX LINE FROM METAL FRAMING STRAP 5) COMPLY WITH ARTICLE 250-522(B)(1), KITCHEN HOOD FANS NOT PERMITTED ON GFCI RECEP