Permit: T01CM02478

Parcel: 136327850

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
11/13/2001 BUILDING - FINAL Approved IVRS - Inspection 0000*
10/30/2001 BUILDING - FINAL Partial Approval IVRS - Inspection 0000*/ 1) PARTIAL PENDING INSTALL OF OVEN, STUCCO AND INSULATION CERTIFICATES
10/24/2001 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) SEWER CLEANOUTS MUST BE TERMINATED WITH THREADED CLEANOUT PLUGS OR CAPS 2) INSTALL RAIN HOOD AT DRYER VENT 3) INSTALL COUNTER TOPS AND PLUMBING FIXTURES 4) INSTALL OVEN 5) INSTALL DISHWASHER 6) SEAL HOLE AT R.A. PLATFORM 7) ALL GARAGE OUTLETS MUST BE GFCI PROTECTED 8) CORD AT HYDRO TUB NOT PER CODE 9) GARAGE LIGHTS MUST BE INSTALLED OR TERMINATE IN ELECTRIC BOX 10) FIRE CAULK GAS LINE IN FIREPLACE 11) A/C DISCONNECT NOT PERMITTED BEHIND UNIT MINIMUM 30" SPACE REQUIRED 12) GAS BOND IS REQUIRED