Permit: T01CM02461

Parcel: 136286460


Addresses:

4400 S DOGWOOD AV

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
11/19/2001 BUILDING - FINAL Approved IVRS - Inspection 0000*
11/05/2001 BUILDING - FINAL Denied IVRS - Inspection 0999*1.) EXTEND T P R @ W/H 2.) NEED GAS TEST2.) ALL EXTERIOR RECP. MUST BE G F I 3. OPEN GROUND @ BATH RECP.
10/24/2001 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) ALL RECEPS AT EXTERIOR MUST BE GFI PROTECTED 2) NEED S.D.'S IN HALL AND ALL BEDROOMS 3) EXTEND PTR 12" 4) NEED GAS TEST 5) I.D. A SERVICE 6) GFI AT BATH
10/22/2001 BUILDING - FINAL Not ready for Inspection IVRS - Inspection 0000*
10/10/2001 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) CLEAN UP WIRING AT EXTERIOR 2) DIG AT WASTE LINE TO SEE CONNECTION 3) NEED 10 LBS TEST ON GAS LINE 4) NEED DOUBLE WALL FLUE AT WATER HEATER WITH 1" CLEARANCE TO COMBUSTIBLE 5) NEED COMBUSTION AND RELIEF FOR WATER HEATER 100 SQUARE FEET IN EACH 6) EXTEND PTR AT LINE 7) EXPOSE FTG. AT COLUMN 8) EXPOSE HOME RUN AND IDENTIFY AT SERVICE
10/01/2001 BUILDING - FINAL Denied IVRS - Inspection 0920*/ 1) NO ANSWER AT DOOR
09/20/2001 BUILDING - FINAL Denied IVRS - Inspection 0920*/ 1) NO ONE HOME
09/12/2001 BUILDING - FINAL Denied IVRS - Inspection 0920*/ 1) NO ANSWER AT DOOR, RE-CALL INSPECTION