Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T01CM02426
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/20/2001 | PLUMBING - FINAL | Approved | IVRS - Inspection 0000*1.) FLUSH HANDLE CORRECTED 2.) EXPANSION TANK SUPPORTED IN AN UNUSUAL, BUT ACCEPTABLE MANNER. 3.) 8" PROBE T & P VALVE OK 4.) UNION ON T&P RELIEF DRAIN OK 5.) OK FOR C OF O. PENDING ANY OTHER INSPECTIONS. | |
09/06/2001 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*THESE ARE THE ONLY RESULTS I COULD ACCESS. 1.) FLUSH HANDLE ON HANDI-CAPPED WATER CLOSET TO BE ON THE SIDE OF THE LARGE OPENING. 2.) EXPANSION TANK TO BE SUPPORTED. 3.) 4" PROBE ON T & P RELIEF VALVE DOES NOT EXTEND INTO THE TANK. 4.) INSTALL A UNION ON T & P RELIEF DRAIN LINE. |