Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 09/20/2001 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000*1.) FLUSH HANDLE CORRECTED 2.) EXPANSION TANK SUPPORTED IN AN UNUSUAL, BUT ACCEPTABLE MANNER. 3.) 8" PROBE T & P VALVE OK 4.) UNION ON T&P RELIEF DRAIN OK 5.) OK FOR C OF O. PENDING ANY OTHER INSPECTIONS. |
| 09/06/2001 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*THESE ARE THE ONLY RESULTS I COULD ACCESS. 1.) FLUSH HANDLE ON HANDI-CAPPED WATER CLOSET TO BE ON THE SIDE OF THE LARGE OPENING. 2.) EXPANSION TANK TO BE SUPPORTED. 3.) 4" PROBE ON T & P RELIEF VALVE DOES NOT EXTEND INTO THE TANK. 4.) INSTALL A UNION ON T & P RELIEF DRAIN LINE. |