Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 03/04/2002 |
ELECTRIC - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000* |
| 01/29/2002 |
ELECTRIC - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection 0000*1.) INTERIOR PARTITIONS OK PARTIAL. |
| 01/28/2002 |
ELECTRIC - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 01/23/2002 |
ELECTRIC - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*1.) PLEASE SUPPORT M/C CABLE AS PER CODE-SWITCH IN WALL AND BOXES IN CEIL, ABOVE PANEL,BELOW PANEL 2.) PROTECTION FOR M/C CABLE IS NEED WHEN LAYED IN HAT CHANNEL 300-4. 3.) EMT FITTINGS ARE LOOSE 4.) A BOX WILL BE NEEDED FOR BATH LIGHT. 5.) SUPPORT CONDUIT ABOVE PANEL AS PER CODE. 6.) AN APPROVED SET OF PLANS NEED TO BE ON THE JOB SITE. |