Permit: T01CM02384

Parcel: 141170950

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T01CM02384

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
07/20/2001 FRAMING Approved IVRS - Inspection 0000*
07/18/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) DOUBLE TRIMMERS NEED SHIMS ON ALL FOUR TRIMMERS FOR FULL BEARING-NOT 2 OUT OF 4
07/17/2001 FRAMING Denied
07/16/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) BLOCK STUD BAY BETWEEN COMBUSTIBLE AND RETURN VENTS 2) TIGHTEN RED HEAD IN SOUTH GARAGE WALL 3) TIGHTEN LOOSE INTERIOR HOLDOWN SOUTHWEST GARAGE CORNER 4) STRAP OVER BORED STUD AT NORTHWEST GARAGE CORNER AT TEMPERATURE RELIEF DRAIN LINE 5) SHIM HEADER AND INSTALL PROPER CRIPPLES IN FRONT BEDROOM 6) STRAP TOP PLATES AT MASTER SINK VENT 7) MOVE PEX 12" FROM MASTER BATH CAN LIGHT 8) BLOCK DUCT BOOT IN KITCHEN 9) REPAIR BOTTOM PLATE AT KITCHEN SINK DRAIN 10) STRAP INSIDE AND OUTSIDE OF TOP PLATES AT HOMERUNS