Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
Permit Number - T01CM02382
Inspection Description - REINFORCED MASONRY PRE-GROUT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/15/2002 | REINFORCED MASONRY PRE-GROUT | Approved | MASONARY PRE GROUT OK. | |
07/12/2002 | REINFORCED MASONRY PRE-GROUT | Denied | IVRS - Inspection 0999* 1.) NO PAPER MESH, OR FILL MATERIAL IN PLACE TO ALLOW POURING OF BOND BEAM. 2.) KEEP VERTICALS CENTERED IN GROUT CELL. 3/4" MINIMUM DISTANCE FROM INSIDE FACE REQUIRED. 3.) DO NOT PLACE FRONT WINDOW FRAMES BEFORE BOND BEAM IS IN PLACE. | |
07/09/2002 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000* | |
06/27/2002 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000*1ST LIFT. |