Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 07/11/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 07/10/2001 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) PROVIDE 1" CLEARANCE FROM COMBUSTIBLE MATERIAL AT FURNACE FLUE PIPE AND CHIMNEY FLUE AND UNIT 2) SEAL RACEWAYS AT PANEL AND ISLAND PENNINSULA 3) INTERIOR ENGINEERED BRACED WALLS OVER KNOTCHED 4) SEAL WEATHER BARRIER TURN BEHIND CHIMNEY |
| 07/05/2001 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) SEE NOTES FROM PREVIOUS INSPECTION 2) ITEMS REQUESTED NOT CORRECTED |
| 07/03/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) PROVIDE EXPANSION BOLTS AT ENTRY AND THRU OUT SINGLE SOLE PLATE SEE UBC 1806.6 2) DRY IN ROOF IN ORDER TO VARIFY COMBUSTIBLE MATERIAL CLEARNACE, INSTALL FLASHING ETC... 3) PROVIDE 30 INCH CLEARANCE WORK SPACE AT HORIZONTAL FURNACE IN ATTIC 4) ISOLATE AND SECURE PEX FROM FRAMING BRACE IN GARAGE 5) DUCT IN KITCHEN NOT SIZED PER PLAN 6) SEAL ISLAND PENNINSULA PVC AT FLOOR |