Permit: T01CM02354

Parcel: 135030200

Inspection Status: Partial Approval

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
05/30/2001 BUILDING - FINAL Partial Approval IVRS - Inspection 0000*/ 1) PORCH IN REAR, FROM LAST INSPECTION, OVER HEAD DROP (ELECT) FROM POWER POLE TO WEATHER HEAD, REQUIRES 8'0" CLEARANCE, NEED TO COMPLY OR HAVE PAPERWORK IE. VARIANCE
05/22/2001 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) PERMITS REQUIRED FOR PORCHES CANNOT APPROVE BUILDING FINAL 2) OUTLET AT STORAGE ROOM IS CONNECTED WRONG HAS AN OPEN GROUND
05/18/2001 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) UNABLE TO INSPECT STORAGE RROM, LOCKED 2) HAVE LICENSED ELECTRICIAN CHECK AND APPROVE EXISTING ELECTRICAL 3) BASE BOARD HEATERS SHALL BE ON SEPARATE CIRCUITS 4) COMB AND RELIEF AIR LACKING IN WATER HEATER AND FURNACE ROOM 5) IS THEIR A RETURN AIR AT FURNACE 6) NEGATIVE FLOW AT WATER HEATER VENT 7) IDENTIFY ALL BREAKERS AT ELECTRICAL SERVER 8) SMOKE DETECTORS MISSING IN BEDROOMS CORRECT AND RECALL FOR INSPECTION 9) FRONT AND REAR PORCH REQUIRE PERMITS, SUBMIT ASBUILT DRAWINGS