Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 05/08/2002 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000*/ 1) SAN TEE IS UPSIDE DOWN 2) COVER PLATE (ELECTRIC) IN CARPORT WALL WIRES ARE CAPPED 3) WILL CHECK BATH THIS AFTERNOON |
| 05/07/2002 |
BUILDING - FINAL |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) USE SAN TEE WITH A 3/4" REDUCER TO CONNECT CONDENSATE SEE DRAWING LAST INSPECTION. OK FOR OLD CODE "94" UPC/UMC 2) 90 DEGREES ELBOW BLOCKS AND RESTRICTS VENT TO KITCHEN |
| 04/26/2002 |
BUILDING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) NO ONE HOME, PLEASE LEAVE INSTRUCTIONS ON REQUEST, VOICE MAIL WHEN YOU CALL IN YOUR INSPECTION OR CONTACT ME ROB 2) PRIOR TO INSPECTION: A) CHANGE OUT ONE THREE PRONG GROUNDED PLUG TO BLADE UNGROUNDED OUTLET B) CAP OFF CLEANOUT UNDER SINK C) NEED 50 FUSES IN A/C DISCONNECT D) PUT THERMOSTAT WIRE IN CONDUIT ROOF JACK E) PERMIT ON OLD CODE DUMP CONDENSATE INTO VENT , OR OFF ROOF TO GROUND F) SECURE AND SUPPORT GAS LINE ON ROOF |