Permit: T01CM02301

Parcel: 116161410


Addresses:

928 N CONTZEN AV

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
07/17/2006 BUILDING - FINAL Approved IVRS - Inspection :*
07/14/2006 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
1) NOT READY-CANCEL PER HOMEOWNER
06/22/2006 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) KITCHEN PENINSULA OVER 6' TO HAVE OUTLET ON END
2) INSTALL ADDRESS NUMBERS ON FRONT OF HOUSE
3) KITCHEN RECEPTACLES TO BE NO MORE THAN 48" APART ALONG WALL LIEN
4) KITCHEN RECEPTACLES TO BE GFCI PROTECTED
5) INSTALL ANTI-SIPHON HOSE BIBS; COMPLETE PLUMBING
6) INSTALL BONDING JUMPER ACCROSS NON MATALLIC A/C BELLOWS
7) KITCHEN OUTLET SHOWS OPEN NUETRAL
8) STOPPED INSPECTION