Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T01CM02294
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/14/2001 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection 0000*NOTES PRIOR TO FINAL, INSTALL A PERMANENT ADDRESS LABEL ON SERVICE. | |
10/19/2001 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection 0999*680-25 D FEEDERS TO A POOL REQUIRED TO BE IN RIGID, IMC, LIQUID THIGHT FLEX, OR PVC CANNOT USE ROMEX. | |
10/16/2001 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*NEED ROMEX CONNECTOR FOR EXHAUST NEED ROMEX CONNECTOR FOR SUB PANEL SUB PANEL NOT ON PLANS PROVIDE ALL APPROVED. |