Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 06/20/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 06/19/2001 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) SECURE OR BLOCK 4 GANG SWITCH AND RECEP BOXES 2) NAIL DOWN SOLE PLATE AT OVER FRAME ENTRY WAY TO BLOCKING BETWEEN TRUSSES 3) FHA STRAP OVER BORE AT DOUBLE TOP PLATE GARAGE GAS LINE 4) BLOCK BETWEEN GIRDER TRUSS AND JACK TRUSS CONNECTION 5) SEAL RACEWAY AT ISLAND PENNINSULA |
| 06/18/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) FIREPLACE FIRESTOP INCOMPLETE 2) INSTALL HINGE BRACING GABLE END WALL AT 6' SPACING 3) SEE DETAIL 1/S4.0 AND COMPLY 4) BLOCKING INCOMPLETE 5) GAS TEST 0 POUNDS 6) SECURE WATER LINES, GAS PIPING OUT OF WALL 7) STOPPED INSPECTION 8) SUPERERINTENDENT TO WALK ALL JOBS PRIOR TO INSPECTION BY CITY OF TUCSON INSPECTOR |