Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 07/13/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 07/09/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) PLAN CALLS FOR 6 X 6 POST AT PORCH CORNER 2) PORCH HEADER AT HOUSE CORNER BEARING ON SINGLE 2 X 6 TRIMMER , SEE 7/D-1 3) GARAGE HEADER NOT STRAPPED PER 7/D-1 4) CLIP ALL HEADERS TO KING STUDS 5) PROVIDE ENGINEERING FOR MISSING HOLDOWN LOCATION EAST WALL TWO EACH 6) SOUTH HOLDOWNS NOT NAILED 7) PROVIDE PROOF OF #1 GRADE FOR PORCH BEAMS 8) ROOF NOT NAILED |