Permit: T01CM02237

Parcel: 113111550


Addresses:

1816 E SENECA ST


Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Permit Number - T01CM02237

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
11/23/2001 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection 0000*
10/15/2001 REINFORCED MASONRY PRE-GROUT Denied IVRS - Inspection 0999*/ 1) MAXIMUM ALLOWED HEIGHT OF GARAGE 12'-0" PRESENTLY 12'-10" HIGH 2) REBAR MUST HAVE 40 ROD DIAMETER OVERLAY. PRESENTLY NO OVERLAP AT CORNERS 3) PLAN CALLS FOR 5/8" DIAMETER LEDGER ANCHORS AT 16" ON CENTER. PRESENTLY 1/2" ANCHOR BOLTS AT 48" ON CENTER AND NOT STAGGARED 4) PLAN CALLS FOR PAT 18 PERLIN ANCHORS AT 48" ON CENTER-NOT INSTALLED 5) STOPPED INSPECTION