Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 06/27/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 06/25/2001 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) AT PREVIOUS INSPECTION SUPERINTENDENT WAS ADVISED THAT ROMEX CABLE HAD BEEN DAMAGED CRIMPED AND THAT THE CABLE SHOULD BE REPLACED AT THIS TIME THE CABLE HAS BEEN RE-SECURED PROTECTIVE COVER IS TORN, CURRENTLY DOES NOT COMPLY WITH NEC 336-16 AND 336-18 2) FLAT CABLES SHALL NOT BE STAPLED ON EDGE AND SHALL BE PROTECTED FROM PHYSICAL DAMAGE 3) RE-INSPECTION FEE DUE PRIOR TO NEXT INSPECTION |
| 06/22/2001 |
FRAMING |
|
Denied |
1) SHEARWALLS MISSING WEDGE ANCHORS 2) EXTERIOR GFCI AT REAR ROMEX NOT MADE UP 3) CRIMPED WIRE AT BEDROOM OPTION 4) SEAL PENETRATIONS AT SOLE PLATE SPLICES 5) TAPE SEAL WEATHER BARRIER WHERE TORN 6) DRAFT STOPS AT KITCHEN FURR DOWN 7) FIRE CHIMNEY FRONT COMBUSTIBLE MATERIAL NEEDS 1" CLEARANCE COMPLETE FRAMING |
| 06/21/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) PREVIOUS INSPECTION REQUEST ITEMS NOT ADDRESSED |
| 06/20/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) DRAFT STOP AND FIRE BLOCKS INCOMPLETE 2) CHIMNEY FLUE PIPE SPARK ARNESTER NOT INSTALLED PROPER COMBUSTIBLE MATERIAL CLEARANCE NOT PROVIDED 3) PROTECT ELECTRIC ROMEX WITHIN 1/4" OF STUD 4) RISER NOT INSTALLED |