Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T01CM02209

Parcel: 116042660

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
08/21/2001 FRAMING Approved IVRS - Inspection 0000*
08/20/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) AT GARAGE REMOVE COMBUSTIBLE MATERIAL FROM FLUE PIPES 2) MISSING AB AT EAST SIDE GARAGE WALL SEE SHEAR WALL SCHEDULE 48" ON CENTER SOUTHWEST 3) SOUTHWEST SHEARWALL CALLS FOR AB'S AT 24" ON CENTER 4) ELECTRICAL BOX HANGING IN KITCHEN 5) TUB NOT GROUTED
08/17/2001 FRAMING Denied IVRS - Inspection 0999*
08/15/2001 FRAMING Denied 1) FIRE BLOCKS 2) REMOVE MESH AT DRYER VENT 3) NAIL SHEAR AT GARAGE WALL 4) ANCHOR BOLTS AT GARAGE WALL 5) BLOCK AIR RETURN GRILL 6) BOLT OR PIN INTERIOR BRG WALLS 7) PROVIDE CLIPS OR STRAPS AT INTERIOR BRG 8) NAIL 45 DEGREE HANGERS 9) CLIP HIP JACKS TO BRG WALL 10) SECURE GAS LINE
08/14/2001 FRAMING Not ready for Inspection 1) NOT READY FOR INSPECTION