Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 08/21/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 08/20/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) AT GARAGE REMOVE COMBUSTIBLE MATERIAL FROM FLUE PIPES 2) MISSING AB AT EAST SIDE GARAGE WALL SEE SHEAR WALL SCHEDULE 48" ON CENTER SOUTHWEST 3) SOUTHWEST SHEARWALL CALLS FOR AB'S AT 24" ON CENTER 4) ELECTRICAL BOX HANGING IN KITCHEN 5) TUB NOT GROUTED |
| 08/17/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* |
| 08/15/2001 |
FRAMING |
|
Denied |
1) FIRE BLOCKS 2) REMOVE MESH AT DRYER VENT 3) NAIL SHEAR AT GARAGE WALL 4) ANCHOR BOLTS AT GARAGE WALL 5) BLOCK AIR RETURN GRILL 6) BOLT OR PIN INTERIOR BRG WALLS 7) PROVIDE CLIPS OR STRAPS AT INTERIOR BRG 8) NAIL 45 DEGREE HANGERS 9) CLIP HIP JACKS TO BRG WALL 10) SECURE GAS LINE |
| 08/14/2001 |
FRAMING |
|
Not ready for Inspection |
1) NOT READY FOR INSPECTION |