Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING ABOVE CEILING
Permit Number - T01CM02195
Inspection Description - BUILDING ABOVE CEILING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/11/2001 | BUILDING ABOVE CEILING | Approved | IVRS - Inspection 0000* | |
10/09/2001 | BUILDING ABOVE CEILING | Denied | IVRS - Inspection 0935*1.) INSTALL CEIL GRID PER U.B.C. 2.) PAY REINSPECTION FEE @ 201 N STONE. | |
10/05/2001 | BUILDING ABOVE CEILING | Denied | IVRS - Inspection 0999*INSTALL CEILING GRID PER UBC 25-2. 1.) REMOVE SCREWS FROM TRACK. | |
10/04/2001 | BUILDING ABOVE CEILING | Denied | IVRS - Inspection 0999*PLEASE INSTALL CEIL GRID WIRES ACCORDING TO UBC 25. | |
10/02/2001 | BUILDING ABOVE CEILING | Denied | IVRS - Inspection 0999*1.) PERIMETER HANGERS (WITHIN 8" OF WALL) REQUIRED @ FITTING ROOM WALL, BOTH SIDES. 2.) FLOURESCENT LIGHTS IN SOUTH END OF BUILDING REQUIRE SAFETY (SIESMIC) HANGERS 3.) KEEP CONDUIT OFF CEILING GRID. |