Permit: T01CM02189

Parcel: 137338780


Addresses:

1911 W BAGLEY WY

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
08/27/2001 BUILDING - FINAL Approved IVRS - Inspection 0000*
08/20/2001 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) PROVIDE ACCESS/WORKSPACE PER UPC SEC 511 MINIMUM OPENING SHALL BE 24 INCHES 2) SEE UPC 608-5 FOR PRESSURE RELIEF TERMINATIONS 3) PROVIDE 3" CLEARANCE FROM TOP OF AC CONDENSOR PLATFORM TO GROUND 4) SEAL BORED HOLE AT NORTH WEST CORNER EAVE BLOCK 5) PROVIDE SILICONE SEAL OVER EXTERIOR LIGHT FIXTURES SEE MANUFACTURERS SPECIFICATIONS LEAVE BOTTOM OPEN TO ALLOW MOISTURE TO ESCAPE 6) POST TENSION TAG NOT INSTALLED AT PYW 7) IDENTIFY BRANCH CIRCUIT FOR GARAGE RECEP NOT GFCI PROTECTED 8) DISHWASHER DRAIN LINE NOT INSTALLED 8) PLUG KNOCKOUT AT AIR HANDLER OPTIONAL CONDENSATION LINE