Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 08/27/2001 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 08/20/2001 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) PROVIDE ACCESS/WORKSPACE PER UPC SEC 511 MINIMUM OPENING SHALL BE 24 INCHES 2) SEE UPC 608-5 FOR PRESSURE RELIEF TERMINATIONS 3) PROVIDE 3" CLEARANCE FROM TOP OF AC CONDENSOR PLATFORM TO GROUND 4) SEAL BORED HOLE AT NORTH WEST CORNER EAVE BLOCK 5) PROVIDE SILICONE SEAL OVER EXTERIOR LIGHT FIXTURES SEE MANUFACTURERS SPECIFICATIONS LEAVE BOTTOM OPEN TO ALLOW MOISTURE TO ESCAPE 6) POST TENSION TAG NOT INSTALLED AT PYW 7) IDENTIFY BRANCH CIRCUIT FOR GARAGE RECEP NOT GFCI PROTECTED 8) DISHWASHER DRAIN LINE NOT INSTALLED 8) PLUG KNOCKOUT AT AIR HANDLER OPTIONAL CONDENSATION LINE |