Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 09/21/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 09/12/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) ALL METAL ELECTRIC BOXES MUST BE GROUNDED 2) ALL ELECTRIC GROUNDS MUST BE INTERNECTED AND SECURED WITH A MECHANICAL FASTNER 3) ALL LIGHT SWITCHES MUST BE GROUNDED 4) REMOVE ALL FIXTURES FROM BOXES FOR INSPECTION OF WIRING/GROUNDS 5) ALL ELECTRIC OUTLETS AND BOXES IN GARAGE MUST BE AT LEAST 18" ABOVE FLOOR 6) LEDGER BOARDS HAVE A35 CLIPS AT EACH STUD 7) REVISE PLAN FOR ADDED 220 VOLT CIRCUIT IN GARAGE 8) UFER GROUND NOT CONNECTED |
| 08/21/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) ALL CLIPS AND HOLDOWNS OK, EXTERIOR SHEATHIN NOT COMPLETE |
| 08/17/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) H2.5 CLIP EVERY OTHER STUD TO LEDGER 2) NAIL SHEATHIN 6" ON SUPPORTED EDGES TO ENDS 12" IN FIELD |