Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T01CM02148

Parcel: 125060120


Addresses:

1933 E 3RD ST

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
09/21/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
09/12/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) ALL METAL ELECTRIC BOXES MUST BE GROUNDED 2) ALL ELECTRIC GROUNDS MUST BE INTERNECTED AND SECURED WITH A MECHANICAL FASTNER 3) ALL LIGHT SWITCHES MUST BE GROUNDED 4) REMOVE ALL FIXTURES FROM BOXES FOR INSPECTION OF WIRING/GROUNDS 5) ALL ELECTRIC OUTLETS AND BOXES IN GARAGE MUST BE AT LEAST 18" ABOVE FLOOR 6) LEDGER BOARDS HAVE A35 CLIPS AT EACH STUD 7) REVISE PLAN FOR ADDED 220 VOLT CIRCUIT IN GARAGE 8) UFER GROUND NOT CONNECTED
08/21/2001 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/ 1) ALL CLIPS AND HOLDOWNS OK, EXTERIOR SHEATHIN NOT COMPLETE