Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T01CM02140

Parcel: 125170170

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
06/26/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
06/22/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) ANCHOR BOLTS REQUIRED WITHIN 12" OF SILL PLATE ENDS AND SPLICES 2) TWO ANCHOR BOLTS REQUIRED IN EACH SILL PLATE MINIMUM 3) SPLICE IN DOUBLE TOP PLATE MUST BE SUPPORTED BY BEARING MEMBER BELOW 4) CORNERS WITH NON OVER LAPPING DOUBLE TOP PLATES MUST BE PROPERLY STRAPPED 5) PROVIDE CITY OF TUCSON APPROVED ENGINEERING TRUSS DRAWINGS 6) OSB ROOF SHEATHING MUST BE INSTALLED WITH GRAIN PER PENDICTULAR TO SUPPORTING TRUSSES ONE PANEL IN NORTHWEST CORNER INSTALLED PARALLEL