Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T01CM02113
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/11/2002 | ELECTRIC - FINAL | Approved | IVRS - Inspection 0000* | |
05/15/2002 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0999* 1.) HOOD NEEDS A CONNECTOR FOR NM CABLE ENTERING COMPARTMENT. 2.) EXTENDER RINGS ARE NEEDED FOR ANY DEVICES EXTENDING MORE THAN 1/8" INTO COMBUSTABLE 3.) KITCHEN RECEPTICALES TO BE GFI PROTECTED. 4.) PLEASE SELA AROUND OUTSIDE LIGHT FIXTURE TO MAINTAIN WETHERPROOF. 5.) PROTECT CONDUCTORS ENTERING BATH BAR. 6.) BATH BAR DOES NOT HAVE A LISTING LABEL. PLEASE VERIFY. | |
11/14/2001 | ELECTRIC - FINAL | Partial Approval | 1.) GFI TO BE ON SEPERATE 20 AMP CIRCUIT 210-11 (C) (3) OK EXTERIOR WALL ONLY. | |
08/08/2001 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0999*1.) OPEN UP INTERIOR WALLS FOR INSPECTION 2.) PLEASE REVISE DRAWING TO REFLECT WORK AT PROJECT. | |
07/23/2001 | ELECTRIC - FINAL | Denied | 1.) NEED PLANS ON SITE. 2.) OPEN UP WALL TO SEE WIRING IN WALLS 3.) NEED UNITS ADDRESSED 4.) WHERE ARE PERMITS FOR OTHER UNITS. |