Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T01CM02095

Parcel: 115201840


Addresses:

1943 W LESTER ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
08/10/2009 PLUMBING - FINAL Approved IVRS - Inspection :*
08/07/2009 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
08/05/2009 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE PIPE PRIMER THEN TAPE AT ALL UNDERGROUND FITTINGS AND TOOL MARK ON STEEL PIPING
2) SUPPORT PIPING ON ROOF
3) EXTEND WATER HEATER VENT TO 3' ABOVE TOP OF COOLER INTAKE WHEN WITHIN 10' WITH APPROVED DBL WALL VENT PIPING AND VENT CAP