Permit: T01CM02062

Parcel: 116022220


Addresses:

2721 W LEAWOOD DR


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T01CM02062

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
10/25/2001 FRAMING Approved IVRS - Inspection 0000*
10/09/2001 FRAMING Denied 1) PROVIDE FIRE BLOCKING AT CHIMNEY 2) OK-TO INSULATE AT DRYWALL EXCEPT CHIMNEY
10/08/2001 FRAMING Denied 1) STRAP BEAMS TO POST AT BAY WONDOW 2) FIRE STOP AT FIREPLACE CHASE 3) ALL INTERIOR ELECTRIC OK CHECK SERVICE PANEL AT FINAL
10/05/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) CLIP BEAMS AT PANEL 2) BLOCK ALL MECHANICAL 3 SIDES 3) STRAP EAST CORNER OF WALL TOP PLATE 4) PROTECT PLUMBING WITH BANG PLATE 5) INSTALL DRYER VENT 6) EXHAUST FAN IN BATH NEED TO TERMINATE TO DAYLIGHT 7) 2 X 6 OVER NOTCHED BEHIND NB 8) CLIP TRUSSES FROM DOOR TO LAUNDRY ROOM 9) ELECTRICAL NOT COMPLETE