Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: ROOF NAILING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/07/2002 |
ROOF NAILING |
|
Approved |
IVRS - Inspection 0000* |
| 11/05/2002 |
ROOF NAILING |
|
Partial Approval |
IVRS - Inspection 0000*1.) H.3 CLIPS NEEDED IN MECH ROOM RAFTER TO LEDGER 2060/2.2. 2.) DECK FASTENING DOES WITH PUDDLE WELDS PER GSN ON 2.3. PROVIDE RFI FOR BUTTON PUNCH 12" O.C. FOR SIDE LAPS IN LIEU OF #10 SCREWS. 3.) INSTALL MECH SUPPORTS PER 321/2.3 |