Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T01CM02029

Parcel: 129070840

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T01CM02029

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
06/22/2001 FRAMING Approved IVRS - Inspection 0000*
06/21/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) PTR LINE SHALL TERMINATE 6" MINIMUM 24" MAXIMUM FROM SLAB 2) SECURE GAS LINE AT LAUNDRY WITH 2 X FRAME 3) FIRE STOP CHASE AT FRONT ENTRY, AT CHANNELS AND HALL BATH
06/20/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) PROVIDE 10 PSI GAS LINE TEST 2) NO WATER TEST 3) ELECTRIC WIRING AT LIVING ROOM NOT COMPLETE 4) SHOWER NOT INSTALLED 5) PROVIDE MINIMUM OF 1' FIRE BLOCKING AT KITCHEN
06/18/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) NOT READY FOR INSPECTION
06/15/2001 FRAMING Not ready for Inspection IVRS - Inspection 0000*