Permit: T01CM02019

Parcel: 141111030

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T01CM02019

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
08/14/2001 FRAMING Approved IVRS - Inspection 0000*
08/13/2001 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) PROVIDE DETAIL FOR 4 X 4
NOTCHING AT KITCHEN AND ENGINEERING FOR PAGE D-1
08/09/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) TIGHTEN AND NAIL OFF INTERIOR H.D.'S 2) SUPPLY TRUSS CALC'S 3) STRAP TOP PLATE PEX CUT AT KITCHEN 4) PATCH SLAB AT KITCHEN SINK TO DRAIN 5) 4 X 4 OVERNOTCHED FOR KITCHEN SINK 6) ATTACH OUTLET IN REAR LEFT BEDROOM 7) TAPE TORN DUCT IN UPSTAIRS CHASE 8) REMOVE OSB FROM FLUE-1ST FLOOR AND ROOF 9) SHIM HEADERS WHERE NEEDED