Permit: T01CM01996

Parcel: 11305108A

Inspection Status: Partial Approval

Inspection History: FRAMING

Date Description Inspector Results Comments
02/21/2003 FRAMING Partial Approval IVRS - Inspection 0000*
02/18/2003 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) MASTER BEDROOM ONLY THIS INSPECTION
12/12/2002 FRAMING Not ready for Inspection IVRS - Inspection 0000*
08/16/2002 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) NO CHANGE
06/28/2002 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) ROOF SYSTEM PER PLAN OK TO DRY IN ROOF 2) ITEMS 2,4 AND 6 FROM 6/18/02 INSPECTION NOT COMPLIED WITH
06/18/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) PLAN CALLS FOR 2 X 10 JOIST ON STUDIO. 2 X 4 JOISTS INSTALLED 2) 1/SD2 REQUIRES STEEL JOISTS TO BEAR ON SOLID GROUTED BOND BEAM 3) SILL PLATE IN NICH NOT PROPERLY ANCHORED REQUIRE ANCHOR BOLTS WITHIN 12" OF ENDS AND SPLICES AND EVERY 32" ON CENTER 4) JOISTS IN BEDROOM AND NITCH REQUIRE BLOCKING BETWEEN JOIST 5) BEDROOM PLAN REQUIRES 2 X 10 JOIST. TJI'S INSTALLED 6) JOIST A66 ANGLE CLIPS HAVE BEEN CUT 7) YOU MUST BUILD TO PLAN OR HAVE PLAN REVISED AND APPROVED TO AS BUILT
06/14/2002 FRAMING Denied IVRS - Inspection 0925*/ 1) NO CITY OF TUCSON APPROVED PLAN ON SITE YOU MUST PROVIDE APPROVED PLANS FOR NEXT INSPECTION