Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Partial Approval
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 02/21/2003 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000* |
| 02/18/2003 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) MASTER BEDROOM ONLY THIS INSPECTION |
| 12/12/2002 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 08/16/2002 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) NO CHANGE |
| 06/28/2002 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) ROOF SYSTEM PER PLAN OK TO DRY IN ROOF 2) ITEMS 2,4 AND 6 FROM 6/18/02 INSPECTION NOT COMPLIED WITH |
| 06/18/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) PLAN CALLS FOR 2 X 10 JOIST ON STUDIO. 2 X 4 JOISTS INSTALLED 2) 1/SD2 REQUIRES STEEL JOISTS TO BEAR ON SOLID GROUTED BOND BEAM 3) SILL PLATE IN NICH NOT PROPERLY ANCHORED REQUIRE ANCHOR BOLTS WITHIN 12" OF ENDS AND SPLICES AND EVERY 32" ON CENTER 4) JOISTS IN BEDROOM AND NITCH REQUIRE BLOCKING BETWEEN JOIST 5) BEDROOM PLAN REQUIRES 2 X 10 JOIST. TJI'S INSTALLED 6) JOIST A66 ANGLE CLIPS HAVE BEEN CUT 7) YOU MUST BUILD TO PLAN OR HAVE PLAN REVISED AND APPROVED TO AS BUILT |
| 06/14/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0925*/ 1) NO CITY OF TUCSON APPROVED PLAN ON SITE YOU MUST PROVIDE APPROVED PLANS FOR NEXT INSPECTION |