Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 08/06/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 07/27/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) EXTERIOR SHEATHIN AT GABLE ENDS NOT INSTALLED AS PER MANUFACTURERS SPECIFICATIONS PROVIDE MANUFACTURERS INSTALLATION INSTRUCTIONS 2) INTERIOR WALLS NOT SECURE LOOSE THRU-OUT 3) POST TO BEAM CONNECTIONS ARE NOT LISTED BY APPROVED AGENCY 4) DRAFT STOPS AND FIRE BLOCKING NOT INSTALLED CORRECT AT KITCHEN 5) BLOCK AROUND MECHANICAL VENTS 3 SIDES MINIMUM 6) CROSS BRACING AT GABLE ENDS NOT NAILED TO ALL WEBS 7) PLUMBING ABS NOT SUPPORTED AT 90 DEGREES KITCHEN VTR NOT CORRECT |