Permit: T01CM01968

Parcel: 132171230

Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Permit Number - T01CM01968

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
06/28/2002 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection 0000*
06/26/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*14'
06/24/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*1.) ENGINEERS CORRECTION FOR #'S BAR UNDER BEAMS @ WINDOWS ACCEPTED.
06/20/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*1.) CLARITY NOTE 5/53.2 CALLING FOR #6 VERTS UNDER BEAMS. YOUR BEAM BEARINGS ARE IN CENTER OF WINDOWS. 2.) MAINTAIN MINIMUM 3/4" CLEARANCE FROM REBAR TO INTERIOR FACE OF BLOCK. 3.) MORTAR FINS SHALL NOT EXTEND MORE THAN 1/2" INTO BLOCK CELLS.
06/19/2002 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection 0000*1.) MAINTAIN MINIMUM 3/4" CLEARANCE FROM VERTICAL REBAR TO INSIDE FACE OF BLOCK.