Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
| Date |
Description |
Inspector |
Results |
Comments |
| 06/28/2002 |
REINFORCED MASONRY PRE-GROUT |
|
Approved |
IVRS - Inspection 0000* |
| 06/26/2002 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000*14' |
| 06/24/2002 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000*1.) ENGINEERS CORRECTION FOR #'S BAR UNDER BEAMS @ WINDOWS ACCEPTED. |
| 06/20/2002 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000*1.) CLARITY NOTE 5/53.2 CALLING FOR #6 VERTS UNDER BEAMS. YOUR BEAM BEARINGS ARE IN CENTER OF WINDOWS. 2.) MAINTAIN MINIMUM 3/4" CLEARANCE FROM REBAR TO INTERIOR FACE OF BLOCK. 3.) MORTAR FINS SHALL NOT EXTEND MORE THAN 1/2" INTO BLOCK CELLS. |
| 06/19/2002 |
REINFORCED MASONRY PRE-GROUT |
|
Not ready for Inspection |
IVRS - Inspection 0000*1.) MAINTAIN MINIMUM 3/4" CLEARANCE FROM VERTICAL REBAR TO INSIDE FACE OF BLOCK. |