Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
Permit Number - T01CM01968
Inspection Description - REINFORCED MASONRY PRE-GROUT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/28/2002 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection 0000* | |
06/26/2002 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000*14' | |
06/24/2002 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000*1.) ENGINEERS CORRECTION FOR #'S BAR UNDER BEAMS @ WINDOWS ACCEPTED. | |
06/20/2002 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000*1.) CLARITY NOTE 5/53.2 CALLING FOR #6 VERTS UNDER BEAMS. YOUR BEAM BEARINGS ARE IN CENTER OF WINDOWS. 2.) MAINTAIN MINIMUM 3/4" CLEARANCE FROM REBAR TO INTERIOR FACE OF BLOCK. 3.) MORTAR FINS SHALL NOT EXTEND MORE THAN 1/2" INTO BLOCK CELLS. | |
06/19/2002 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection 0000*1.) MAINTAIN MINIMUM 3/4" CLEARANCE FROM VERTICAL REBAR TO INSIDE FACE OF BLOCK. |