Permit: T01CM01947

Parcel: 110050380


Addresses:

2951 N SWAN RD #185

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
05/18/2001 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection 0000*1)P.O.C OF NEW BUILDING DRAIN TO EXSISTING BUILDING DRAIN OK.2)SOIL WATER TEST OK.3)OK FOR BACKFILL.
05/17/2001 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999*1)APPROVED PLAN CALLS FOR 4" VTR.2)DIRTY ARM FOR WET VENTED LAV. CAN ONLY BE 1 PIPE SIZE LARGER THAN ALLOWED TRAP SIZE.SEE SECTION:1003.3 94 UPC.3)RETEST SYSTEM.