Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T01CM01947
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/18/2001 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection 0000*1)P.O.C OF NEW BUILDING DRAIN TO EXSISTING BUILDING DRAIN OK.2)SOIL WATER TEST OK.3)OK FOR BACKFILL. | |
05/17/2001 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection 0999*1)APPROVED PLAN CALLS FOR 4" VTR.2)DIRTY ARM FOR WET VENTED LAV. CAN ONLY BE 1 PIPE SIZE LARGER THAN ALLOWED TRAP SIZE.SEE SECTION:1003.3 94 UPC.3)RETEST SYSTEM. |