Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 06/21/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 06/20/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) INSTALL GAS BOND WIRE INSIDE FRAME WALLS INTO BACK OF PANEL 2) COMPLETE ALL NUMBERED ITEMS ABOVE |
| 06/19/2001 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) ISOLATE UPPER AND LOWER COMBUSTION AIR 2) 2 X 8 HEADER NOT COMPLETE AT ENTRY 3) BLOCK AND SHEAR AT SHEARWALL KNOTCH BEHIND HALL BATH 4) PROVIDE TRIMMER AT NORTHWEST CORNER BEARING WALL OR PROVIDE ENGINEER'S EVALUATION AND APPROVAL 5) PROVIDE 1" CLEARANCE FROM COMBUSTIBLE MATERIAL TO TYPE B-FLUE PIPES 6) PROVIDE TWO 2X'S UNDER GIRDER ENTRY WAY 7) DRAFTSTOP LAUNDRY FURR DOWN |
| 06/18/2001 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) FRONT ENTRY CALLS FOR DOUBLE 2 X 8, YOU HAVE 2 X 6 10'-6" SPAN HAVE HEADER SIZE CHECKED 2) NEED TRUSS DRAWINGS FOR INTERIOR LOAD BEARING 3) NO WATER TEST 4) NEED GIRDER HANGER SIZE GARAGE 5) CHECK BEARING END TRUSS GARAGE 6) STRAP WATER LINES AT ENTRY WINDOW 7) NEED GIRDER TO TRUSS HANGER ON PLAN USE CORRECT NAILS AND FILL ALL HOLES 8) NEED GAS BOND 9) GAS PRESSURE OK |