Permit: T01CM01938

Parcel: 136327070

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
06/21/2001 FRAMING Approved IVRS - Inspection 0000*
06/20/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) INSTALL GAS BOND WIRE INSIDE FRAME WALLS INTO BACK OF PANEL 2) COMPLETE ALL NUMBERED ITEMS ABOVE
06/19/2001 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) ISOLATE UPPER AND LOWER COMBUSTION AIR 2) 2 X 8 HEADER NOT COMPLETE AT ENTRY 3) BLOCK AND SHEAR AT SHEARWALL KNOTCH BEHIND HALL BATH 4) PROVIDE TRIMMER AT NORTHWEST CORNER BEARING WALL OR PROVIDE ENGINEER'S EVALUATION AND APPROVAL 5) PROVIDE 1" CLEARANCE FROM COMBUSTIBLE MATERIAL TO TYPE B-FLUE PIPES 6) PROVIDE TWO 2X'S UNDER GIRDER ENTRY WAY 7) DRAFTSTOP LAUNDRY FURR DOWN
06/18/2001 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) FRONT ENTRY CALLS FOR DOUBLE 2 X 8, YOU HAVE 2 X 6 10'-6" SPAN HAVE HEADER SIZE CHECKED 2) NEED TRUSS DRAWINGS FOR INTERIOR LOAD BEARING 3) NO WATER TEST 4) NEED GIRDER HANGER SIZE GARAGE 5) CHECK BEARING END TRUSS GARAGE 6) STRAP WATER LINES AT ENTRY WINDOW 7) NEED GIRDER TO TRUSS HANGER ON PLAN USE CORRECT NAILS AND FILL ALL HOLES 8) NEED GAS BOND 9) GAS PRESSURE OK