Permit: T01CM01910

Parcel: 141113540

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Permit Number - T01CM01910

Inspection Description - BUILDING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
09/20/2001 BUILDING - FINAL Approved IVRS - Inspection 0000*
09/18/2001 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) SEVERAL EXTERIOR OUTLETS ARE MIS-WIRED 2) CANNOT DOUBLE TAP NEUTRALS IN PANEL 3) CAN ONLY DOUBLE TAP #14 AND #12 CV WIRES-NOT #10 4) REMOVE OR CAP VENT THAT IS PRIOR TO THE TRAP IN MAIN CONDENSATE DRAIN LINE (ATTIC) 5) REMOVE MINOR AMOUNT OF LOOSE FILL FROM SECONDARY CONDENSATE PAN
09/17/2001 BUILDING - FINAL Not ready for Inspection IVRS - Inspection 0000*