Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 05/02/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 04/30/2002 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) GAS AND WATER LINES MUST BE ELECTRICALLY BONDED WITH CLAMP EXPOSED 2) 1" CLEARANCE REQUIRED TO COMBUSTIBLE ROOF SHEATHING (FURNACE) 3) NAIL PROTECT WIRES WITHIN 1 1/4" OF WALL SURFACE (EAST CLOSET) (K) 4) ELECTRIC OUTLET NOT ALLOWED UNDER COUNTER W/ 6" OR MORE OVERHANG 5) BOND JACCUZI PUMP TO COPPER #8 6) K. RECESSED LIGHT IN CONTACT W/COPPER 7) GAS METER NOT RELOCATE |
| 03/13/2002 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) STUDIO BATHROOM OK TO ROCK |