Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T01CM01766
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/09/2001 | BUILDING - FINAL | Approved | IVRS - Inspection 0000* | |
08/07/2001 | BUILDING - FINAL | Denied | IVRS - Inspection 0999*/ 1) PROVIDE 6" CLEARANCE TP RELIEF VALVE DRAIN TO EARTH 2) PROVIDE 4" CLEARANCE FROM STUCCO WEEP SCREED TO EARTH 3) SECURE FURNACE FLUE 1" CLEAR FROM FOAM MATERIAL AND SECURE TO DIVERTER 4) REMOVE EMPTY RECEP BOX FROM EAST GARAGE WALL 5) LAUNDRY ROOM EXHAUST FOR NOT OPERABLE 6) PROVIDE MANUFACTURER LISTING FOR JACUZZI MOTOR |