Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 06/27/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 06/26/2001 |
FRAMING |
|
Denied |
1) COMPLETE ELECTRIC ROMEX THRU OUT SHOULD TERMINATE IN A BOX SEE NEC 70/169 FOR INSTALLATIONS 2) PROTECT ROMEX FROM PHYSICAL DAMAGE OR NAIL PENETRATIONS 3) GFCI RECEP FOR BATHROOMS SHALL ONLY HAVE RECEPS ON CIRCUIT 4) KITCHEN COUNTER TOP RECEPS SHALL BEGIN WITHIN 24 INCHES OF COUNTER ENDS AND 48 INCHES ON CENTER 5) SECURE 4 GANG ELECTRIC BOXES 6) PROVIDE ALL PREVIOUS INSPECTION FORMS SEE NOTE ON PERMIT CARD 7) PROVIDE EXPANSION BOLTS WITHIN 12 INCHES OF SOLE PLATE SPLICES AT EXTERIOR WALLS 8) COMPLETE ROMEX FOR JACUZZI TUB 9) DRAFT STOP AND FIRE BLOCK AT KITCHEN FURR DOWN |
| 06/25/2001 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) REQUIRES SMOKE DETECTORS |