Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T01CM01741

Parcel: 126060990


Addresses:

4209 E IRVING CI

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
09/16/2003 FRAMING Approved IVRS - Inspection 0000*
11/27/2002 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) HOUSE OK, GARAGE NOT READY, OK TO INSULATE AND DRYWALL HOUSE
11/20/2002 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) BLOCK FIREPLACE CHASE 2) INSULATION AT PIPE INTO F/P BACK SIDE 2) CHANGE NAILS IN DOUBLE HANGERS TO GLU LAM 4) REMOVE OUTLET AT COUNTER OVER HANG 5) BANG PLATE ALL PLUMB, STRAP DRYER DUCT 6) 3-12 PITCH MINIMUM FOR A RIDGE BOARD, NEEDS A BEAM OR ADD ON TO RIDGE