Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T01CM01702

Parcel: 126171150


Addresses:

3926 E MONTECITO ST

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
07/10/2001 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection 0000*
07/06/2001 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection 0000*1.) DONT RUN SEWER TRUNK IN PARALLEL WITH FTG. 2.) DONT USE SANT ON IT BACK VERTICAL POSITION ONLY 3.) KEEP TRAP ARM SAME SIZE (DIA) PIPE FROM VERT DRAIN VENT 4.) LONG SWEEP GOING VERT TO HUTIZ, 1/4 OR HORIZ TO VERT. USE LONG SWEEP LYING FLAT AT 90 TURNS. 5.) FLOOR DRAIN 2" NEEDS TRAP PRIMER, SUGGUST FRENCH DRIAN SEE SKETCH 6.) NEED 2 WAY CLEAN OUT SEE DRAWING.